Gate Valve Size and Pressure Class Chart: Class 150 to 2500

Industrial gate valves are specified by nominal size, pressure class, materials and end connections. Understanding how these details work together helps engineers and procurement teams prepare accurate enquiries and compare technically suitable offers.



This gate valve size and pressure class chart covers common nominal sizes from NPS 2 to NPS 24, pressure classes from 150 to 2500, and reference face-to-face dimensions for selected flanged gate valves.


Pressure class is not the allowable working pressure in psi. The pressure permitted for a valve depends on its material, temperature, construction and applicable rating standard.

The numerical values below are reference information, not an approved valve datasheet. Confirm pressure-temperature ratings against the applicable edition of ASME B16.34 and final dimensions against the manufacturer’s approved general arrangement drawing before selection or fabrication.


Gate Valve Sizes: NPS to DN Conversion


NPS and DN are nominal size designations. They identify corresponding piping sizes; neither should be treated as an exact measurement of the valve bore.


Common equivalents include:


  • NPS 2: DN 50

  • NPS 2½: DN 65

  • NPS 3: DN 80

  • NPS 4: DN 100

  • NPS 6: DN 150

  • NPS 8: DN 200

  • NPS 10: DN 250

  • NPS 12: DN 300

  • NPS 14: DN 350

  • NPS 16: DN 400

  • NPS 18: DN 450

  • NPS 20: DN 500

  • NPS 24: DN 600


Small-bore gate valves are commonly available in forged construction, while larger industrial gate valves are often cast. However, size alone does not determine construction. Forged and cast designs can overlap, depending on the manufacturer and specification.

For operating principles and component details, read What Is a Gate Valve?.


What Does Gate Valve Pressure Class Mean?

ASME pressure classes identify pressure-temperature rating groups. Common designations include Class 150, 300, 600, 900, 1500 and 2500.


For example, Class 150 does not mean 150 psi. A standard-class carbon steel valve can have an ambient-temperature pressure rating above 150 psi, while its allowable pressure generally decreases as temperature rises.


The material also matters. Carbon steel, stainless steel and alloy steel valves of the same class may have different pressure-temperature limits.


Reference Pressure Ratings: Class 150 to 2500

The following rounded values are commonly published for standard-class carbon steel materials such as ASTM A216 WCB and ASTM A105 in ASME material Group 1.1, at the low-temperature reference range of approximately −29°C to 38°C.


  • Class 150: Approximately 19.6 bar or 285 psi

  • Class 300: Approximately 51.1 bar or 740 psi

  • Class 600: Approximately 102.1 bar or 1,480 psi

  • Class 900: Approximately 153.2 bar or 2,220 psi

  • Class 1500: Approximately 255.3 bar or 3,705 psi

  • Class 2500: Approximately 425.5 bar or 6,170 psi


Bar and psi figures are rounded independently. These values do not establish suitability for every valve carrying the same class marking.


Confirm the material specification, rating category, applicable standard edition and any manufacturer limitations. Low-temperature material suitability, including any impact-testing requirements, must also be assessed separately.


How Temperature Changes the Pressure Rating

A valve’s pressure rating must be checked at the design temperature, not only at ambient temperature.


The following rounded carbon steel reference values illustrate the trend. All pressures are in bar.


At 38°C

  • Class 150: 19.6 bar

  • Class 300: 51.1 bar

  • Class 600: 102.1 bar

At 100°C

  • Class 150: 17.7 bar

  • Class 300: 46.6 bar

  • Class 600: 93.2 bar

At 200°C

  • Class 150: 13.8 bar

  • Class 300: 43.8 bar

  • Class 600: 87.6 bar

At 300°C

  • Class 150: 10.2 bar

  • Class 300: 39.8 bar

  • Class 600: 79.6 bar

At 400°C

  • Class 150: 6.5 bar

  • Class 300: 34.7 bar

  • Class 600: 69.4 bar


These figures illustrate why a pressure class that appears adequate at ambient temperature may be unsuitable for a hot line.


They are not a substitute for the current material-specific rating table. Elevated-temperature material selection must also consider the applicable piping code, service duration and project requirements.

Gate Valve Face-to-Face Dimensions

Face-to-face length is the distance between the specified end faces of a valve. For a replacement valve, this dimension must match the installation requirements.

The following reference lengths are commonly used for flanged, raised-face gate valves. Dimensions are in millimetres and must be checked against the applicable ASME B16.10 configuration and approved drawing.


The order below is Class 150 / Class 300 / Class 600.

  • NPS 2: 178 / 216 / 292 mm

  • NPS 3: 203 / 283 / 356 mm

  • NPS 4: 229 / 305 / 432 mm

  • NPS 6: 267 / 403 / 559 mm

  • NPS 8: 292 / 419 / 660 mm

  • NPS 10: 330 / 457 / 787 mm

  • NPS 12: 356 / 502 / 838 mm

  • NPS 14: 381 / 762 / 889 mm

  • NPS 16: 406 / 838 / 991 mm

  • NPS 18: 432 / 914 / 1,092 mm

  • NPS 20: 457 / 991 / 1,194 mm

  • NPS 24: 508 / 1,143 / 1,397 mm


Do not automatically apply these values to butt-weld, ring-type joint or other valve configurations. Confirm the relevant dimensional series, end details and measurement reference.


The approved drawing should also identify flange dimensions, overall height, handwheel or actuator clearance, weight and any installation-specific requirements.


Which Standards Apply?

Different standards address different parts of the valve specification.

ASME B16.34: Addresses requirements for covered valve constructions, including pressure-temperature ratings.

ASME B16.10: Addresses face-to-face and end-to-end dimensions for covered valve types and configurations.

ASME B16.5: Addresses covered pipe flanges and flanged fittings. Its general size scope extends from NPS ½ through NPS 24, but Class 2500 flanges are covered only through NPS 12. Larger Class 2500 connections require an appropriately specified alternative arrangement. ASME B16.5 scope


The product design standard and testing requirements must also be stated where applicable. Listing a standard does not mean every material, size, pressure class and end connection is available in every combination.


How to Choose the Right Gate Valve Size and Class

1. Confirm the Required Nominal Size

Identify the line size and required bore configuration from the approved piping specification.

Nominal valve size alone does not establish flow capacity or confirm that the internal bore meets the project requirement.

2. Establish Design Pressure and Temperature

Use the specified design conditions rather than relying only on normal operating conditions. Include relevant start-up, shutdown or upset cases identified by the engineering design.

3. Select the Material and Check Its Rating

Confirm the body material and its allowable pressure at the design temperature.

The proposed class must satisfy the applicable piping specification, code and project requirements. Pressure rating is one part of selection; compatibility, corrosion allowance, trim and other service requirements also matter.

4. Confirm the Connections

For flanged valves, check the mating flange standard, class, facing, dimensions, bolting and gasket requirements.

For welding ends, confirm the pipe schedule, end preparation and welding requirements.

5. Check Installation Dimensions

Confirm face-to-face or end-to-end length, operating clearance, support requirements and maintenance access before fabrication or replacement.

6. State the Inspection and Documentation Scope

Include the applicable design and testing requirements, leakage acceptance criteria, material records and any agreed inspection stages.

For wedge-design considerations, read Solid, Flexible and Split Wedge Gate Valves Explained.


Worked Example: Reviewing a Hot-Oil Requirement


Consider an illustrative requirement for a 6-inch line with a design pressure of 30 bar at 250°C.


A Class 150 carbon steel rating would be below the stated pressure at that temperature.

A commonly published standard-class Group 1.1 table gives approximately 41.9 bar for Class 300 at 250°C. This is a tabulated reference value—not a claim that the valve has been selected or approved for the application.


For the referenced NPS 6, Class 300 flanged raised-face configuration, the listed face-to-face length is 403 mm.


Before selection, confirm:

  • The pressure-temperature rating in the applicable standard edition.

  • Material suitability for the hot-oil service.

  • Required trim, packing and sealing performance.

  • End-connection compatibility.

  • Dimensions on the approved drawing.

  • Applicable design, testing and project requirements.

The pressure comparison is only one step in determining suitability.


Gate Valve Requirements from KPI Valves


KPI Valves manufactures industrial valves in Chandarda, Mahesana, Gujarat, India.

Explore the KPI gate valve range for product information. The available size, pressure class, design standard, material, operation and end connections should be confirmed for the configuration quoted.

Do not assume that every advertised size is available in every pressure class or connection type.


Frequently Asked Questions


Is Class 150 the Same as 150 psi?

No. Class 150 is a pressure-temperature rating designation. The allowable pressure depends on the material, temperature and applicable valve rating requirements.

What Is the Pressure Rating of a Class 150 Carbon Steel Gate Valve?

A commonly published standard-class Group 1.1 reference is approximately 19.6 bar or 285 psi at the low-temperature reference range. Confirm the rating for the exact material, temperature and valve construction.

Does DN 100 Mean an Exact 100 mm Bore?

No. DN 100 is a nominal size designation corresponding to NPS 4. The actual bore depends on the valve and piping design.

What Is the Face-to-Face Length of a 4-Inch Class 150 Gate Valve?

A commonly used reference length for the specified flanged raised-face configuration is 229 mm. Confirm the applicable dimensional series and the manufacturer’s approved drawing before installation.

Can I Replace a Valve Using Only Its Size and Class?

No. Also check material, trim, end connections, flange facing, installation dimensions, operation, service suitability and testing requirements.

Are All Class 2500 Flanges Covered up to NPS 24 by ASME B16.5?

No. ASME B16.5 covers Class 2500 flanges only through NPS 12. Larger connections require an appropriately specified alternative.


Need a Gate Valve Datasheet or Quotation?

Share your valve schedule or datasheet with the required size, class, materials, design pressure, design temperature, end connections and quantity.


For replacements, include the existing valve details and installation dimensions wherever available.

Contact KPI Valves for technical review and quotation, or email sales@kpivalve.com.

Comments


  • Whatsapp
  • Instagram
  • Facebook
  • LinkedIn

 9am - 5pm

(Thursdays - Closed)

Plot no . 393, Chandarda Ghumasan Approach Road, Chandarda, Near Ahmedabad Mahesana Expressway, Ta-Kadi, Dist- Mahesana,

Gujarat-382705

bottom of page